Bobcat Service Analyzer v89.12 Diagnostic Tool – with Kg 07.2022

Bobcat Service Analyzer v89.12 Diagnostic Tool – with Kg 07.2022

Description
Last update: 07.2022
Size: 358 Mb
Region: All regions
Type: Diagnostic and calibration tool for Bobcat Equipment
Language: English, Spanish, Italian, Portuguese, Russian, Chinese, German, Czech, French
OS: Win 7, Win Vista, Win XP, Win 10
Instructions: Present
Installation: 1 PC (by TeamViewer)
Number of discs: 1 CD
Version: v89.12
Instant download after payment, no waiting
High speed download link

Bobcat Service Analyzer contains a tool for programming and diagnosing the Bobcat technique. Software version 89.xx contains a list of fixes and updates that you can read for a better understanding of the program.

Diagnostic tools Bobcat help you find out whether there is a problem with our equipment and solve in time with the diagnostic tool to avoid potential danger. This software will allow you to familiarize yourself with the various technical information and functions of this program, with which you can correctly diagnose your equipment and prevent premature breakdowns.

Diagnostic tools Bobcat is intended for programming, diagnostic, service log, and calibration:
– Software updates
– Change SN/Options
– Clear Controller Data.
– Drive pump calibration status
– Panel
– Remote Control
– System
– Vitals,
– Edit diagnostic screens
– Interactive tests and etc.
With help step by step instructions, you can do diagnostic your equipment.
Service Analyzer Bobcat a very simple interface, support multilanguage includes English and recorded on 1 DVD-DL, which consists of basic standard tools. Below you can see release notes.

Service Analyzer V89.02 – 8 Mar 2021

  1. Eliminate intermittent H3948 Multiple Joystick
    fault that can occur during cold cranking on
    M-Series loaders.
  2. New M-Series Loader Auxiliary Software (V5.03)
    a. Updated Fuel Lift Pump Control for Bobcat V1
    Engines
    – T770HB: AT6330000+ – T740HA: B3CA21000+
    – S770HB: AT5A17000+ – T870HC: B47C18000+
    – S740HA: B3BT19000+ – S850HC: B47715000+
    – T770HEB: B3BW16000+ – S770HEB: B3BV14000+
    – T870HEC: B47L14000+ – S850HEB: B3BY14000+

Service Analyzer V89.01 – 11 Feb 2021

  1. Update Aux2 and Aux4 flow settings and load
    moment setting for the following R-Series
    compact excavators:
    – E50ZLER: B4HT11001+ – E50ZFR: B4TC11001+ – E55ZLER: B4HU11001+
    – E55ZF
    R: B4TD11001+
    – E60LER: B4HV11001+
  2. Adds options for High Flow, and Electric Aux
    and Offset to the following Compact Excavator:
    – E17ZK*CM: B4ZM11001+
  3. Adds engine diagnostic screen for Compact
    Excavators.
  4. New M-Series Loader Workgroup Software (V11.13)
    a. Fixes issue with intermittent W3276 fault.
  5. Adds support for new M-Series Loader Workgroup
    controller P/N 7314576.
  6. New Attachment Controller (SACD) Software (V1.3)
    a. Adds support for Super Flow attachments.

b. Adds support for the following attachments:
– 72SCH: S6TE00001+
– 72SCHHF: A6TD00001+
– 84SCH: A6TG00001+
– 84SCHHF: A6TH00001+
– SB26X36: B53M00001+
– SB26X48: B53N00001+
– SB26X56: B53P00001+
– SB32X60: B55P00001+
– SB32X68: B53H00001+
– SB32X74: B53G00001+
– SB32X80: B53J00001+
– SB32X86: B55V00001+
– SB36X86: B53K00001+
– SB36X96: B53L00001+
– FRC50: B57M00001+
– FRC61_1SPD: B5CB00001+
– FRC61_2SPD: B57L00001+
– FRC72: B5CA00001+
– SG60: 233000001+
– SG60X: A00700001+
– VBLADE60: 084300001+
– VBLADE72: 083900001+
– VBLADE84: 084000001+
– VBLADE96: 084100001+
– VBLADE108: 084200001+
– BACKHOE: 074600001+
– DOZER80: 232100001+
– DOZER90: 231900001+
– DOZER96: 224400001+

  1. Update for the following M-Series loaders
    to show “PRIME” on display when fuel system
    is priming:
    – S450HDC: B4RH11001+
    – T450HDB: B4RG11001+
    – S510HDB: B4RE11001+
    – S590HDB: B4RF11001+
    – T550HDA: B57T11001+
    – T595HDA: B57U11001+
  2. Support for S590HDA move from Korea region
    to North America region.
    – B4TP11001 – B4TP12000: South Korea
    – B4TP12001+ : North America
  3. Support for new engine map files on the
    following machines:
    – E88JAR: B4NM11001+
    – E88LER: B4NL11001+

Service Analyzer V89.00 – 21 Jan 2021

  1. New R-Series Compact Excavator Standard Display
    Software (V1.16.4)
    a. Improved display stability.
  2. New R-Series Loader Standard Display
    Software (V1.16.3)
    a. Improved display stability.

Service Analyzer V88.24 – 4 Dec 2020

  1. Support added for S70K*CB (S/N: B57B11001+)
  2. Updated ECU Software
    a. Disable Low Oil Level Fault (P350F)

b. Adjust Low Idle RPM (850RPM to 950RPM)

The above affects the following machines with
Bobcat V2 engines
– R-Series Loaders: 6X/7X
– Excavators: E42/D42, E50/D50, E50Z, E55Z, E60

  1. New R-Series loader update
    a. Support added for single direction bucket
    positioning.

b. Support added for Workgroup Response.

Service Analyzer V88.23 – 3 Nov 2020

  1. New R-Series Loader Standard Display Software
    (V1.16.0)
    a. Improved display stability.

b. Reduces instances where camera screen wasn’t
mirroring image properly.

c. Fixed issue where vitals would overlap with
icon.

d. Renamed “Workgroup Settings” to “Lift and Tilt
Compensation”

e. Fixed issue where three point seatbelt icon would
remain active after two speed was deactivated.

  1. New R-Series Compact Excavator Standard Display
    Software (V1.16.1)
    a. Improved display stability.

b. Reduces instances where camera screen wasn’t
mirroring image properly.

c. Fixed issue where vitals would overlap with
icon.

d. Fixed issue where machine lockout and Quick Start
were not allowed to be changed while engine was
running.

Service Analyzer V88.14 – 17 July 2020

  1. New Small Articulated Loader (SAL) main
    controller software (V1.05)
    a. Support for service clock and service
    clock log.

b. Adjustment to the sensor supply out of
range faults.

c. Updaed hydraulic oil temperature warning and
shutdown setpoints (High 195°F, Extremely
High 210°F).

d. Auxiliary pot out of neutral fault will clear on
next attempt to actvate auxiliary if pot is within
the neutral range.

e. Extend and Retract out of neutral fault will clear
on the next attempt to activate extend or retract if
pot is within the neutral range.

f. Arm bar faults require a key cycle to clear.

g. Support for software version log.

h. Support for engine hour meter rollover. Hour meter
will roll over to 0 when 9999.9 is reached.

i. Updates to service analyzer diagnostic screens
and fault code descriptions.

  1. Fixed issue where some ECU map files were not properly
    linked causing the following error to appear on
    Service Analyzer No application file available for Engine
    Control Unit (ECU)

Service Analyzer V88.11 – 2 July 2020

  1. Increases coil current for Soil Asphalt
    Spreader.
  2. Corrected depth check errors for the
    following excavator models:
    D42JR: B4YF00001+ E42JR: B4GM00001+
  3. New AWS Loader Drive+ software (V12.3)
    a. Support for new steering solenoids
  4. Updated Engine (ECU) Software for
    DL01, DL02, DL03 Bobcat Engines
    a. Fuel Injector valve cleaning logic
    added to ECU map files for original
    piston and pre-TMAP sensor equipped
    original Bobcat Engines.
  5. Updated the following Bobcat Engine,
    V2 ECU map files:
    a. Fixed issue with EGR / TVA H-Bridge
    open load fault codes not clearing
    after repair.
    – Loader
    DM02_LEL00_A06_V721
    DM02_LEL01_A02_V721
    DM02_LEL02_A03_V721
    DM02_LEL06_A05_V721
    DM02_LEL07_A02_V721
    DM02_LEL08_A02_V721
    DM02_MFL01_A03_V721
    DM02_MFL02_A04_V721
    DM02_MFL03_A02_V721
    DM02_MFL04_A02_V721
    DM02_MFL08_A04_V721

– Excavator
DM01_LEE00_A05_V721_ECU
DM01_LEE01_A05_V721_ECU
DM02_LEE01_A02_V721_ECU

– Telehandler
DM03_LEV00_A02_V721_ECU
DM03_MFV01_A02_V721_ECU

  1. Adjusted starter engine speed cut off
    level from 1000 RPM to 850 RPM on the
    following machines:
    – S450LDEA: B4J711001+ – S450HDC: B4RH11001+ – T450LDEA: B4J611001+
    – T450HDB: B4RG11001+
    – S510LDEA: B4JB11001+ – S510HDB: B4RE11001+ – S530LDEA: B4KA11001+
    – S550LDEA: B4ZD11001+ – S590LDEA: B4ZE11001+
    – S590HDB: B4RF11001+
    – T590LDEA: B4KV11001+ – T550HDA: B57T11001+ – T595HD*A: B57U11001+
  2. New Gauge panel software (V3.05)
    a. Support for Telehandler Bobcat Engine V2
  3. New R-Series Loader Hub Software (V1.13)
    a. Support for added for Bobcat Engine V2
    with DPF.
  4. New R-Series Touch Display Software
    (Application: V2.5.0; Content: V1.5.0)
    a. Support for added for Bobcat Engine V2
    with DPF.

b. Fixed issue where fuel usage statistics
is showing incorrect data.

  1. New R-Series Standard Display Software
    (Application V1.12.0)
    a. Support for added for Bobcat Engine V2
    with DPF.

Service Analyzer V87.07 – 22 May 2019

  1. New TLS Gateway Software (V6.40), TLS Drive
    Software (V6.40) and TLS Workgroup Software
    (V6.40) to support new controllers with part
    numbers 7273600, 7273601, and 7273602.
  2. New Manbasket Software (V1.40) and GACD2
    Software (V1.20) to support new controller
    with part number 7273603.
  3. Support added for the following machines:
    – D35JR: B4WV11001+ – D35ZKER: B4CS11001+
    – D42J
    M: B4WW11001+ – D42JR: B4YF11001+ – D50JM: B4WY11001+
    – D50
    J**R: B4YG11001+
  4. Support added for 7″ Display on the
    following machines:
    – E85J*R: B48413701+

Service Analyzer V87.06 – 14 May 2019

  1. New GACD Software (V8.9)
    a. Support added for the Box Blade HD
    – B4T900101+
  2. New Loader Deluxe Software (V7.5)
    a. Support added for the Box Blade HD
  3. New MX Primary (V4.5) and Secondary (V2.3) software
    a. Initial support for 7″ display

b. Support for the following machines:
– D17ZKAM: B3Y911001+ – D27ZKER: B4BB11001+
– D35ZK*ER: B4CS11001+


Service Analyzer V87.05 – 30 April 2019

  1. Support for Bob-Dock added on the
    following machines:
    – S740HA: B3BT11805 – T740HA: B3CA11805
    – S770HB: AT5A11720 – T770HB: AT6312720
    – A770HB: AT5J11380 – T750HB: AT5T11743
    – T630HB: AJDT13778 – T650HB: ALJG19317
    – S630HB: AHGL12984 – S650HB: ALJ818497
  2. Support added for the following
    machines:
    – E26K*R: B4S911001
  3. New Loader M4 Drive Software
    (V14.11)
    a. Decrease hydrostatic pump gain
    for the following models:
    – T630A – A7PU16275+ – T630HB – AJDT16750+
    – T650A – A3P021700+ – T650
    EA – A3P115475+
    – T650H*B – ALJG29650+ – T650HEB – B2KZ13900+

Service Analyzer V87.04 – 5 April 2019

  1. Support for Bob-Dock added on the
    following machine:
    – T650H***B: ALJG28632
  2. Boom down movement control ramps
    improved on following Telehandler
    machines:
    – TL35.70: ANL714000+, ANMG14000+,
    AVM114000+, AVM614000+,
    B3ZS11001+, B3ZT11001+
    – TH.7035: AR3914000+, AR3D14000+,
    B3C414000+, B3C514000+,
    B3ZZ11001+, B41111001+
    – V723: B4C311001+
  3. Corrected boom movement limitations
    in case of some LLM faults on following
    Telehandler models:
    TL30.60, TL26.60, TH.6030, TL30.70, TH.7030,
    T35.105, T35.105L, T36.120SL, T35.130S,
    T35.130SLP, T35.140S, T41.140SLP, T40.180SLP

Service Analyzer V87.03 – 27 March 2019

  1. Support added for the following
    machines:
    – S70KB: B4TY11001+
    – S70K
    EB: B4UC11001+ – S590HDA: B4TP11001+ – E26K**R: B4S911001+
  2. New Loader Gateway Software
    (V15.01)
    – Fixes issue with switched power
    sometimes remaining off on key on.

Service Software V87.02 – 4 Mar 2019

  1. New Loader Auxiliary Software
    (V5.1)
    – Fixes issue with Remote ACD
    attachments (Chipper, Concrete
    Pump, etc.) when activating
    auxiliaries from the attachment.
  2. Support for Bob-Dock added on the
    following machines
    – S740HA: B3BT14668+ – T740HA: B3CA15491+
    – S770HB: AT5A13544+ – T770HB: AT6319318+
    – S770HEB: B3BV11888+ – T770HEB: B3BW13133+
    – A770HB: AT5J12503+ – A770H**EB: B3BU11707+ – T630HB: AJDT16592+
    – S630HB: AHGL14606+ – S650HB: ALJ825891+
  3. Include boom float option on
    following TLS machines:
    – TL26.60 B3G615001+, B3G815001+,
    B3GA15001+, B3GC15001+,
    B3YF15001+, B3ZH15001+
    – TL30.60 B3G415001+, B3G715001+,
    B3G915001+, B3GB15001+,
    B3YD15001+, B3Z815001+
    – TL30.70 B4AY15001+, B4AZ15001+,
    B4B215001+, B4B315001+
    – TH.6030 B3GD15001+, B3GE15001+,
    B3GF15001+, B3GG15001+,
    B3ZL15001+, B3ZM15001+
    – TH.7030 B4DW15001+, B4DZ15001+
    – TL34.65HF B41N17001+, B41P17001+
    – TL35.70 ANL716001+, ANMG16001+,
    AVM116001+, AVM616001+,
    B3ZS17001+, B3ZT17001+
    – TL38.70HF AHT416001+, AVDV16001+,
    AVKJ16001+, AVKM16001+,
    B3ZU17001+, B3ZV17001+
    – TL43.80HF B4BT11001+, B4BU11001+,
    B4BY11001+, B4BZ11001+,
    B4P711001+
    – TH.6534 B41S17001+, B41R17001+
    – TH.7035 AR3916001+, AR3D16001+,
    B3C416001+, B3C516001+,
    B3ZZ17001+, B41117001+
    – TH.7038 AT7A16001+, AVDZ16001+,
    B3C616001+, B3C716001+,
    B41217001+, B41317001+
    – TH.8043 B4BV11001+, B4BW11001+,
    B4C111001+, B4C211001+,
    B4P811001+
  4. Update TLS Bobcat engine ECU
    software to include 300 sec torque
    derate before engine shutdown in
    case of critical failure on
    following machines:
    – TL26.60 B3YG11001+, B3ZJ11001+,
    B3ZH11001+, B3YF11001+,
    – TL30.60 B3YE11001+, B3Z911001+,
    B3Z811001+, B3YD11001+,
    – TL30.70 B4B111001+, B4B211001+,
    B3ZK11001+, B4B311001+
    – TH.6030 B3ZL11001+, B3ZM11001+,
    – TH.7030 B4DW11001+, B4DZ11001+
    – V519 B3YH11001+,
    – TL35.70 B3ZS11001+, B3ZT11001+
    – TL34.65HF B41N11001+, B41P11001+
    – TL38.70HF B3ZU11001+, B3ZV11001+,
    AVDV14000+, AVKJ14000+,
    AHT414000+, AVKM14000+
    – TL43.80HF B4BY11001+, B4BZ11001+,
    B4P711001+, B4BT11001+,
    B4BU11001+
    – TH.7035 B3ZZ11001+, B41111001+
    – TH.6534 B41R11001+, B41S11001+
    – TH.7038 B41211001+, B41311001+,
    AVDZ14000+, AT7A14000+,
    B3C614000+, B3C714000+
    – TH.8043 B4C111001+, B4C211001+,
    B4P811001+, B4BV11001+,
    B4BW11001+
    – V723 B4C311001+
    – T35.105 B41511001+, B41411001+
    – T35.105L B41711001+, B41611001+
    – T36.120SL B41911001+, B41811001+
    – T35.130S B41B11001+, B41A11001+
    – T35.130SLP B41D11001+, B41C11001+
    – T35.140S B41G11001+, B41F11001+
    – T41.140SLP B41K11001+, B41H11001+
    – T40.180SLP B41M11001+, B41L11001+
  5. Service Analyzer V5.17 Release
    – Added warning when TLS engine
    updates require main
    controller updates.

– New engine software included:
300 sec torque derate in case of
critical error code then engine
shutdown instead of immediate
engine shutdown.

– Fixed bug that caused portions of
the English postscript of
translated logs to not be in
English.

– Fixed data from diagnostic
screens being captured when
closing the file dialog, instead
of when the “Save Data” button in
the gear menu was pressed.

– Improved handling of invalid
default service log directory
settings.


Service Software V87.01 – 19 Feb 2019

  1. Reverting Loader Auxiliary Software
    from V5.0 to V4.03. Issue found
    that prevents Remote ACD attachments
    (Chipper, Concrete Pump, etc.) from
    activating auxiliaries from the
    attachment.

Service Software V87.00 – 11 Feb 2019

  1. New Toolcat Drive Software (V4.10)
    a. Improved auxiliary control when
    braking.

b. Improved throttle fault
detection.

c. Improved swash plate fault
detection.

  1. New Loader M4 Drive Software
    (V14.10)
    a. Decrease hydrostatic pump gain
    for the following models:
    – T740HA – B3CA16100+ – T770*A – A3P816575+
    – T770EA – A3P913375+ – T770HB – AT6321000+
    – T770HEB – B3BW13300+ – T870EB – B47H11300+ – T870HC – B47C13700+
    – T870H
    EC – B47L11500+
  2. Telehandler Software Update (Workgroup
    V5.6; Drive V6.1; and Gateway V5.2)
    a. Creation of following serial numbers
    for 4.3 T machines:
    – B4BT11001+
    – B4BU11001+
    – B4BV11001+
    – B4BW11001+
    – B4BY11001+
    – B4BZ11001+
    – B4P711001+
    – B4C111001+
    – B4C211001+
    – B4P811001+

b. Activated automatic suspension
function on following serial numbers:

PF1:
B3G415001+, B3G615001+, B3G715001+
B3G815001+, B3G915001+, B3GA15001+
B3GB15001+, B3GC15001+, B3GD15001+
B3GE15001+, B3GF15001+, B3GG15001+
B3Z815001+, B3ZH15001+, B3YD15001+
B3YF15001+, B3ZL15001+, B3ZM15001+
B4AY15001+, B4AZ15001+, B4B215001+,
B4B315001+, B4DW15001+, B4DZ15001+

PF2:
B41N17001+, B41P17001+, B41R17001+,
B41S17001+, ANL716001+, ANMG16001+,
AVM116001+, AVM616001+, AR3916001+,
AR3D16001+, B3C416001+, B3C516001+,
B3ZS17001+, B3ZT17001+, B3ZZ17001+,
B41117001+, B4C317001+, AVDV16001+,
AHT416001+, AVKJ16001+, AVKM16001+,
AVDZ16001+, AT7A16001+, B3C616001+,
B3C716001+, B3ZU17001+, B3ZV17001+,
B41217001+, B41317001+, B4BT11001+,
B4BU11001+, B4BV11001+, B4BW11001+,
B4BY11001+, B4BZ11001+, B4P711001+,
B4C111001+, B4C211001+, B4P811001+

c. Improved interrupt power monitoring on
Workgroup and Auxiliary controllers